Standard Dimmer – 600W 4SW

R199,00

Lorem Ipsum is simply dummy text of the printing and typesetting industry.

SKU: 600W-4SW Categories: ,

Maximum 600W Resistive – 500W Inductive Minimum 50W.

TROUBLE SHOOTING:

The dimmer gets hot or has a burning smell.
The dimmer is overloaded, turn off and recalculate the load.

The lights flicker
The dimmer is under loaded.
Replace 40watt bulbs with 60watt or
There are electronic transers that are not suitable for dimming.
Electronic transers must be marked “suitable for dimming”.
Use a voltage stabiliser with electronic transers that are noisy or unstable (flicker).

R & D Light Dimmers have been tested for compliance with the S.A.B.S regulations regarding the electro-magnetic interference levels.

CAUTION:
Never connect the dimmer to any earth (green) or neutral (black) wires.
When used on “low voltage” lights connect the dimmer in series with the live wire on the 230V side of the transer and NOT the 12V side.

Switch Configuration